Specifications |
C9600-SUP-1 |
Platform Benefits |
Resiliency and High Availability |
Software Maintenance Upgrade (SMU) Cisco StackWise Virtual Stateful Switchover (SSO) In-Service Software Upgrade (ISSU) Graceful Insertion and Removal (GIR) MKA High Availability |
Enterprise Security |
Trustworthy Solutions Image Signing Secure Boot Cisco Trust Anchor Module MACsec Encryption (256-bit AES-GCM)‚ ‚ Object-Group ACLs (IPv4/IPv6) |
Enterprise QoS |
Modular QoS CLI (MQC) Strict Priority Queuing Class/Color-aware Queuing (WFQ)‚ ‚ Policing/Metering Shaping/Bandwidth Hierarchical QoS (2-level) |
IP Routing |
Routing Information Protocol version 2 (RIPv2), and next generation (RIPng) Open Shortest Path First version 2 (OSPFv2), and OSPFv3 Enhanced Interior Gateway Routing Protocol (EIGRP), and EIGRPv6 Intermediate System-to-Intermediate System Version 4 (IS-ISv4) Border Gateway Protocol version 4 (BGPv4), and BGPv6 Protocol-Independent Multicast (PIM) Sparse- Mode (PIM- SM) Protocol-Independent Multicast (PIM) Source- Specific Mode (PIM-SSM) Bidirectional PIM (BIDIR-PIM) IPv6 routing L3 Routed Sub-Interfaces |
Multi-Protocol Label Switching (MPLS) |
MPLS L3 VPN Ethernet over MPLS (EoMPLS) Virtual Private LAN Service (VPLS) MPLS over GRE MPLS Traffic-Engineering (MPLS-TE) |
Ethernet VPN (EVPN) |
Virtual eXtensible LAN (VXLAN) L2 Virtual Network Interface (VNI) L3 Virtual Network Interface (VNI) Distributed Anycast Gateway EVPN Spine VPN Border EVPN Leaf |
Software-Defined Access (SD-Access) |
Virtual eXtensible LAN (VXLAN) L2 Virtual Network Interface (VNI) L3 Virtual Network Interface (VNI) Distributed Anycast Gateway SDA Control-Plane SDA Border SDA Edge |
Flexible NetFlow (FNF) |
FNF IPv4 flow records FNF IPv6 flow records FNF sampler FNF data export NetFlow version 9 (NFv9) export IPFIX export |
Programmability |
NETCONF RESTCONF gNMI/gNOI YANG models ZTP/PTP |
Smart Operations |
Bluetooth Wireless UI RFID tags Blue beacon Out-of-Band Management |
Operating Temperature |
-5° to 45° C (23° to 113° F) up to 6000 feet -5° to 40° C (23° to 104° F) up to 10,000 feet |
Storage Temperature |
-40° to 75° C (40° to 167° F) |
Relative Humidity, Operating and Non-operating, Non-condensing |
10% to 95%, Non-condensing |
Altitude |
-60 to 3000 m (-197 to 9843 feet) |
Mean Time Between Failures (MTBF) (hours) |
C9606R chassis: 4,113,900 C9606 fan tray: 452,570 C9600-PWR-3KWAC: 300,000 C9600-PWR-2KWAC: 300,000 C9600-PWR-2KWDC: 300,000 |
Safety certifications |
‚ IEC 60950-1 plus Am1, Am2, Am9, Am10, Am11, Am12 and all deviations and differences ‚ AS/NZS 60950.1.2011 ‚ CAN/CSA-C22.2 No. 60950-1-07 ‚ GB 4943-95 ‚ EN 60950-1; 2006 plus Am1, Am 2, Am9, Am10, Am11, Am12 and all deviations and differences ‚ NOM-019-SCFI-1998 ‚ UL 60950-1, Second Edition |
EMI and EMC Compliance |
47 CFR Part 15 Class A CNS13438: 2006 Class A EN 300 386 V1.6.1 EN61000-3-2: 2014 EN61000-3-3: 2013 ICES-003 Issue 6: 2016 Class A KN 32: 2015 Class A TCVN 7189: 2009 Class A EN 55032:2012/ AC:2013 Class A EN 55032:2015 Class A CISPR 32 Edition 2 Class A V-2/2015.04 Class A V-3/2015.04 Class A CISPR24: 2010 + A1: 2015 EN 300 386 V1.6.1 EN55024: 2010 + A1: 2015 KN35: 2015 TCVN 7317: 2003 |