Specifications |
IE-1000-4T1T-LM |
DRAM |
128 MB DDR2 without ECC |
Flash Memory |
160 MB |
Max. Switching Bandwidth |
2.8 Gbps |
Max. Forwarding Bandwidth |
5.6 Gbps |
Alarm |
Alarm I/O: output connector on top panel of 4P2S and 8P2S, 1.0A@24VDC or 0.5A@48VDC |
Power consumption |
4.2W |
Connectors and cabling |
100BASE-FX MMF (2 km)TBD with engineer input 10/100/1000BASE-T ports: RJ-45 connectors, 4-pair Category 5 UTP cabling |
Mean Time Between Failure (MTBF) |
374,052 hours (42.7 years) |
Operating Temperature |
-20 C to 70 C (vented enclosure operating) -20 C to 60 C (sealed enclosure operating) -16 C to 75 C (fan or blower-equipped enclosure operating) |
Storage Temperature |
-40 C to +85 C |
Operating Altitude |
Up to 13.8k ft |
Mean Time Between Failure (MTBF) |
374,052 hours (42.7 years) |
Safety Certifications |
UL/CSA 60950-1 EN 60950-1 CB to IEC 60950-1 (with country deviations) NOM to NOM-019-SCF1 (through partners and distributors) UL/CSA/IEC/EN 61010-2-201 CE Marking |
EMI and EMC compliance |
FCC 47 CFR Part 15 Class A EN 55022/CISPR 22 Class A EN 55016-1-1, -1-4, -2-3 Class AVCCI Class A RoHS compliance AS/NZS CISPR 22 Class A, AS/NZS CISPR 24 CISPR11 Class A, CISPR22 Class A ICES 003 Class A KCC Marking (Korea) CE Marking RCM Marking (Australia/New Zealand) EAC Marking (Eurasian Conformity) Anatel (Brazil) China NAL IEC/EN/EN61000-4-2 (Electro Static Discharge), 8kV air/6kV contact IEC/EN 61000-4-3 (Radiated Immunity, 10 V/m 80-2000MHz, 3V/m 2000-2700MHz) IEC/EN 61000-4-4 (Fast Transients - 2kV DC power, 2kV data line, 4kv earth) IEC/EN 61000-4-5 (Surge 2 kV/1 kV DC power, 2 kV shielded and unshielded data line) IEC/EN 61000-4-6 (Conducted Immunity, 10 V/emf 0.15-80MHz) IEC/EN 61000-4-8 (Power Frequency Magnetic Field Immunity 30A/m 60 sec, 300A/m 3 sec) IEC/EN 61000-4-9 (Pulse Magnetic Field Immunity 300A/m) IEC/EN 61000-4-29 (Voltage Dips Immunity) |
Shock and Vibration |
EC 60068-2-27 (Operational Shock: 30G 11ms, half sine) IEC 60068-2-27 (Non-Operational Shock 65-80G, trapezoidal) IEC 60068-2-6, IEC 60068-2-64 (Operational Vibration) EC 60068-2-6, IEC 60068-2-64, IEC 60068-2-47 (Non-operational Vibration) |
Industry Standard |
IEC/EN 61000-6-1 (Immunity for Light Industrial Environments) IEC/EN 61000-6-2 (Immunity for Industrial Environments) IEC/EN 61000-6-4 (Emissions for Industrial Environments) EN 61131-2 (PLC Zone A & B, EMC/EMI, environmental, mechanical) EN61326-1 (Industrial Controls) Marine TAC (Temp-A, Humid-B, Vib-A, EMC-A, Enc-A) EN 50581 (RoHS) China RoHS EU WEEE NEMA TS-2 (EMC, environmental, mechanical) IP30 |
Hazardous Locations (* Cabinet enclosure required) |
ANSI/ISA 12.12.01 (Class1, Div2 A-D)* EN 60079-0, -15 ATEX certificate (Class 1, Zone2 A-D)* IEC 60079-0, 15 (report only)* UL 60079-0, 15* CAN/CSA C22.2 No. 60079-0, -15* |
Humidity |
IEC 60068 -2-3 IEC 60068-2-30 (Test Db) Relative humidity: 5% to 95% non-condensing |
Add A Review
Your email address will not be published. Required fields are marked