Specifications |
Cisco IE-2000-8T67P-G-E Switch |
Total ports |
10 |
100 MB D-code |
8 |
GE X-code ports |
2 GE |
Manufacturing license |
LAN Base |
IEEE1588 |
X |
NAT |
X (Requires LAN Base to LAN Enhanced image (enables Layer 2 NAT)) |
PoE (+) |
X |
Hardware |
● 256MB DRAM with ECC memory |
● IEEE 1588v2 FPGA |
● 64MB on-board flash memory |
● 1GB removable SD flash memory card (optional) |
Alarm |
● Alarm-one alarm output relay using an M12 A Coded 5 Pin connector (Max. rated: 24VDC @ |
1A/48VDC @ 0.5A) |
Input voltage supported |
with PoE: 44-57VDC |
Dimensions (H x W x D) |
9.5” x 9.32” x 3.9” (241.7 x 236.7 x 99 mm) |
Weight |
7.19 lbs. (3.26 kg) |
Cisco IE 2000 software features - LAN Base license (Default) |
Layer 2 switching |
IEEE 802.1, 802.3, 802.3at, 802.3af standard (see Table 8), VTPv2, NTP, UDLD, CDP, LLDP, |
Unicast MAC filter, Flex Link, REP, VTPv3, EtherChannel, Voice VLAN |
Security |
SCP, SSH, SNMPv3, TACACS+, RADIUS Server/Client, MAC Address Notification, BPDU |
Guard, SPAN session (1), Port-Security, DHCP Snooping, Dynamic ARP Inspection, IP |
Source Guard, 802.1x, Guest VLAN, MAC Authentication Bypass, 802.1x Multi-Domain |
Authentication, Storm Control, Trust Boundary |
Multicast |
IGMPv1, v2, v3 Snooping, IGMP filtering, IGMP Querier |
QoS |
IPv4 Ingress Policing, Rate-Limiting, Egress Queuing/Shaping, AutoQoS |
Management |
Fast Boot, Express Setup, Web Device Manager, CNA, Cisco Prime, LMS, MIB, SmartPort, |
SNMP, Syslog, Port- Based DHCP, Storm Control-Unicast, Multicast, Broadcast, SPAN |
Sessions (2), RSPAN, DHCP Server, Customized TCAM/SDM Size Configuration |
Industrial Ethernet |
Ethernet/IP, Profinet, Profinet MRP, IEEE 1588 PTPv2 |
IPv4 routing |
IPv4 static routing |
IPv6 routing |
IPv6 host support, HTTP over IPv6, SNMP over IPv6 |
Industrial Management (Enhanced LAN Base) |
Layer 2 Switching with 1:1 static NAT |
(IP Lite license) IPv4 Routing |
RIP, OSPF, EIGRP, VRF Lite |
(IP Lite license) IPv6 Routing |
IPv6 Static routing, OSPFv3 |
Compliance specifications |
Safety certifications |
● UL/CSA 60950-1 |
● EN 60950-1 |
● CB to IEC 60950-1 with all country deviations |
● NOM to NOM-019-SCFI (through partners and distributor) |
● CCC (for power supply only) (Pending) |
Industrial (control equipment) floor |
● UL 508 |
● CSA C22.2, No 142 |
● CSA C22, 2 No 107.1 (for Power Supply Only) |
Operating environment |
● Operating Temperature: -40C to +60C |
● EN 60068-2-1 |
● EN 60068-2-2 |
● EN 61163 |
● Altitude: Up to 13,800 feet or 4,200 meters |
EMC emissions and |
● FCC 47 CFR Part 15 Class A |
immunity compliance |
● EN 55011 |
|
● EN 55022A Class A |
|
● VCCI Class A |
|
● AS/NZS CISPR 22 Class A |
|
● CISPR 11 Class A |
|
● CISPR 22 Class A |
|
● ICES 003 Class A |
|
● CNS13438 Class A |
|
● KN22 |
|
● EN55024 |
|
● CISPR 24 |
|
● AS/NZS CISPR 24 |
|
● KN24 |
|
● Brazil ANATEL certification |
|
● EN 61000-4-2 Electro Static Discharge |
|
● EN 61000-4-3 Radiated RF |
|
● EN 61000-4-4 Electromagnetic Fast Transients |
|
● EN 61000-4-5 Surge |
|
● EN 61000-4-6 Conducted RF |
|
● EN 61000-4-8 Power Frequency Magnetic Field |
|
● EN 61000-4-9 Pulse Magnetic Field |
|
● EN 61000-4-10 Oscillatory Magnetic Field |
|
● EN-61000-4-29 DC Power Voltage Dips and Immunity |
Shock and vibration |
● IEC 60068-2-6 Vibration: IEC 60068-2-6, IEC 255 21.1 Class 1 Vibration Test |
● IEC 60068-2-27 (Shock) |
● IEC 60068-2-31 (Shock) |
● IEC 60068-2-32 (Shock) |
● IEC 60068-2-64 (Vibration) |
● EN 61373 Cat 1 Class B (Shock and Vibration) |
Industry standards |
● EN 61000-6-2 Industrial |
● EN 61000-6-4 Industrial |
● EN 61000-6-1 Light Industrial |
● EN 61326 Industrial Control |
● EN 61131-2 Programmable Controllers |
● Marine (DnV) ENV3 (Pending) |
● EN 60945 Maritime navigation and radio equipment and systems (Pending) |
● IEEE 1613 Electric Power Stations Communications Networking (Pending) |
● IEC 61850-3 Electric Substations Communications Networking (Pending) |
◦ EN 50155 EMC, EMI Environmental and Mechanical, galvanic isolation on uplinks (g1/1 g1/2) only |
● EN 45545-3 Fire Safety in Railway Vehicles |
● EN 45545-2 Fire Protection |
● EN50121-4 Railway-Signaling and Telecommunications Apparatus |
● EN50121-3-2 Railway-Apparatus for Rolling Stock |
● NEMA TS-2 DC Power Traffic Control Equipment (Pending) |
● ODVA Industrial EtherNet/IP |
● ABB Industrial IT Certificate |
● IP67 (per EN60529) |
● NEMA 4 (per UL 50E) |
Corrosive testing |
● ISO 9223: Corrosion |
● class C3-Medium |
● ISO 9223: Corrosion |
● class C4-High |
● EN 60068-2-52 Salt mist testing |
Humidity |
● IEC 60068-52-2 (Salt Fog Mist, Test Kb) marine environments |
● IEC 60068 -2-3 |
● IEC 60068-2-30 |
● Relative humidity: 5% to 95% noncondensing |
Operating temperature |
● -40°C to +75°C |
● -40°C to +70°C (vented enclosure operating) |
● -40°C to +60°C (sealed enclosure operating) |
● -34°C to +75°C (200 LFM or more fan- or blower-equipped enclosure operating) |
● -40°C to +85°C (type tested to +85°C for 16 hours) |
● Altitude: Up to 13,800 feet (4570 meters) |
Storage temperature |
● -40°C to +85°C |
● IEC 60068-2-14 |
● Altitude: Up to 13,800 feet or 4,200 meters |
MTBF |
● Mean time between failures: 374,052 hours (42.7 years) |
Management and Standards |
IEEE standards |
● IEEE 802.1D MAC Bridges, STP |
● IEEE 802.1p Layer2 COS Prioritization |
● IEEE 802.1q VLAN |
● IEEE 802.1s Multiple Spanning-Trees |
● IEEE 802.1w Rapid Spanning-Tree |
● IEEE 802.1x Port Access Authentication |
● IEEE 802.1AB LLDP |
● IEEE 802.3ad Link Aggregation (LACP) |
● IEEE 802.3af Power over Ethernet provides up to 15.4W DC power to each end device |
● IEEE 802.3at Power over Ethernet provides up to 25.5W DC power to each end device |
● IEEE 802.3af Power over Ethernet |
● IEEE 802.3at Power over Ethernet Plus |
● IEEE 802.3x full duplex on 10Base-T |
● IEEE 802.3 10BASE-T specification |
● IEEE 802.3u 100BASE-TX specification |
● IEEE 802.3ab 1000BASE-T specification |
● IEEE 1588v2 PTP Precision Time Protocol |
RFC compliance |
● RFC 768: UDP |
● RFC 783: TFTP |
● RFC 791: IPv4 protocol |
● RFC 792: ICMP |
● RFC 793: TCP |
● RFC 826: ARP |
● RFC 854: Telnet |
● RFC 951: BootP |
● RFC 959: FTP |
● RFC 1157: SNMPv1 |
● RFC 1901, 1902-1907 SNMPv2 |
● RFC 2273-2275: SNMPv3 |
● RFC 2571: SNMP Management |
● RFC 1166: IP Addresses |
● RFC 1256: ICMP Router Discovery |
● RFC 1305: NTP |
● RFC 1492: TACACS+ |
● RFC 1493: Bridge MIB Objects |
● RFC 1534 DHCP and BootP interoperation |
● RFC 1542: Bootstrap Protocol |
● RFC 1643: Ethernet Interface MIB |
● RFC 1757: RMON |
● RFC 2068: HTTP |
● RFC 2131, 2132: DHCP |
● RFC 2236: IGMP v2 |
● RFC 3376: IGMP v3 |
● RFC 2474: DiffServ Precedence |
● RFC 3046: DHCP Relay Agent Information Option |
● RFC 3580: 802.1x RADIUS |
● RFC 4250-4252 SSH Protocol |
SNMP MIB objects |
● BRIDGE-MIB |
● CALISTA-DPA-MIB |
● CISCO-ACCESS-ENVMON-MIB |
● CISCO-ADMISSION-POLICY-MIB |
● CISCO-AUTH-FRAMEWORK-MIB |
● CISCO-BRIDGE-EXT-MIB |
● CISCO-BULK-FILE-MIB |
● CISCO-CABLE-DIAG-MIB |
● CISCO-CALLHOME-MIB |
● CISCO-CAR-MIB |
● CISCO-CDP-MIB |
● CISCO-CIRCUIT-INTERFACE-MIB |
● CISCO-CLUSTER-MIB |
● CISCO-CONFIG-COPY-MIB |
● CISCO-CONFIG-MAN-MIB |
● CISCO-DATA-COLLECTION-MIB |
● CISCO-DHCP-SNOOPING-MIB |
● CISCO-SNMP-TARGET-EXT-MIB |
● CISCO-STACK-MIB |
● CISCO-STACKMAKER-MIB |
● CISCO-STP-EXTENSIONS-MIB |
● CISCO-SYSLOG-MIB |
● CISCO-TCP-MIB |
● CISCO-UDLDP-MIB |
● CISCO-VLAN-IFTABLE-RELATIONSHIP-MIB |
● CISCO-VLAN-MEMBERSHIP-MIB |
● CISCO-VTP-MIB |
● ENTITY-MIB |
● ETHERLIKE-MIB |
● HC-RMON-MIB |
● IEEE8021-PAE-MIB |
● IEEE8023-LAG-MIB |
● IF-MIB |
● IP-FORWARD-MIB |
● CISCO-ENTITY-ALARM-MIB |
● CISCO-ENTITY-VENDORTYPE-OID-MIB |
● CISCO-ENVMON-MIB |
● CISCO-ERR-DISABLE-MIB |
● CISCO-FLASH-MIB |
● CISCO-FTP-CLIENT-MIB |
● CISCO-IF-EXTENSION-MIB |
● CISCO-IGMP-FILTER-MIB |
● CISCO-IMAGE-MIB |
● CISCO-IP-STAT-MIB |
● CISCO-LAG-MIB |
● CISCO-LICENSE-MGMT-MIB |
● CISCO-MAC-AUTH-BYPASS-MIB |
● CISCO-MAC-NOTIFICATION-MIB |
● CISCO-MEMORY-POOL-MIB |
● CISCO-PAE-MIB |
● CISCO-PAGP-MIB |
● CISCO-PING-MIB |
● CISCO-PORT-QOS-MIB |
● CISCO-PORT-SECURITY-MIB |
● CISCO-PORT-STORM-CONTROL-MIB |
● CISCO-PROCESS-MIB |
● CISCO-PRODUCTS-MIB |
● CISCO-RESILIENT-ETHERNET- PROTOCOL- MIB |
● CISCO-RTTMON-ICMP-MIB |
● CISCO-RTTMON-IP-EXT-MIB |
● CISCO-RTTMON-MIB |
● CISCO-RTTMON-RTP-MIB |
● IP-MIB |
● LLDP-EXT-MED-MIB |
● LLDP-MIB |
● NETRANGER |
● NOTIFICATION-LOG-MIB |
● OLD-CISCO-CHASSIS-MIB |
● OLD-CISCO-CPU-MIB |
● OLD-CISCO-FLASH-MIB |
● OLD-CISCO-INTERFACES-MIB |
● OLD-CISCO-IP-MIB |
● OLD-CISCO-MEMORY-MIB |
● OLD-CISCO-SYS-MIB< |
● OLD-CISCO-SYSTEM-MIB |
● OLD-CISCO-TCP-MIB |
● OLD-CISCO-TS-MIB |
● RMON-MIB |
● RMON2-MIB |
● SMON-MIB |
● SNMP-COMMUNITY-MIB |
● SNMP-FRAMEWORK-MIB |
● SNMP-MPD-MIB |
● SNMP-NOTIFICATION-MIB |
● SNMP-PROXY-MIB |
● SNMP-TARGET-MIB |
● SNMP-USM-MIB |
● SNMP-VIEW-BASED-ACM-MIB |
● SNMPv2-MIB |
● TCP-MIB |
● UDP-MIB |
|
|
|
|
Add A Review