Specifications |
IE-3300-8P= |
Power Consumption |
14W (Power consumption for non PoE supported model is measured at 12V and for the PoE supported model is measured at 54V.) |
Operating Temperature |
-40°C to +70°C (40 LFM vented enclosure) -40°C to +60°C (sealed enclosure) -34°C to +75°C (Min. 200 LFM fan or blower-equipped enclosure) +85°C (type tested for 16 hours) |
Storage Temperature |
-40 C to +85 C |
Operating Altitude |
Up to 15,000 feet |
Storage Altitude |
15,000 feet |
Mean Time Between Failures (MTBF) |
2,931,233 |
Industrial Automation Control System |
IEC 62443-4-1 IEC 62443-4-2 |
Electromagnetic emissions |
FCC 47 CFR Part 15 subpart B Class A EN 55032/CISPR 32 Class A VCCI Class A AS/NZS CISPR 32 Class A CISPR 11 Class A ICES 003 Class A CNS 13438 Class A KN 32 Class A EN 300 386 |
Electromagnetic immunity |
CISPR 24 EN 55024 KN 35 EN 61000-4-2 Electro Static Discharge (air 15kV, contact 8kV) EN 61000-4-3 Radiated RF (10V/m UTP, 20V/m STP) EN 61000-4-4 Electromagnetic Fast Transients (4kV) EN 61000-4-5 Surge (2KV/1KV Power, 4KV STP) EN 61000-4-6 Conducted RF (10Vrms UTP) EN 61000-4-10 Damped Oscillatory Magnetic Field (100 A/m) EN 61000-4-16 Conducted CM Disturbances (30V, Cont/300V, 1 sec) EN 61000-4-17 Ripple Immunity DC Power (10%) EN 61000-4-18 Damped Oscillatory Wave (2.5kV, 1MHz) EN-61000-4-29 DC Voltage Dips and interruptions |
Industry standards |
EN 61000-6-2 Industrial Immunity EN 61000-6-4 Industrial Emissions EN 61000-6-1 Light Industrial Immunity EN 61326-1 Measurement, Control and Laboratory Equipment IEEE 1613 Electric Power Stations Communications Networking EN/IEC 61850-3 Electric Substations Communications Networking EN50121-4 Railway Signaling and Telecommunications Apparatus EN50155- Railway applications - Rolling stock ODVA Industrial EtherNet/IP NEMA TS 2-2016 IP30 |
Marine I |
DNC Certification according to class guideline DNV-CG-0339 Additional Standards: IEC 60945, IACS UR E10 |
Safety standards and certifications
|
Information technology equipment: UL/CSA 60950-1, IEC 60950-1 CB with all country deviations UL/CSA 62368-1, IEC 62368-1 CB with all country deviations Industrial floor (control equipment): UL/CSA 61010-2-201 CB report and certificate to IEC/EN 61010-2-201 Hazardous locations: UL121201 (Class l, Div 2, groups A-D) CSA 213 (Class l, Div 2, groups A-D) UL/CSA 60079-0, -15 (Class l, Zone 2, Gc/IIC) IEC 60079-0, -15 IECEx test report (Class l, Zone 2, Gc/IIC) EN 60079-0, -15 ATEX certificate (Class l, Zone 2, Gc/IIC) Cabinet enclosure required |
Humidity |
Relative humidity of 5% to 95% non-condensing IEC 60068-2-78 IEC 60068-2-30 |
Shock and vibration |
IEC 60068-2-27 (operational shock, 50G, 3ms, half sine) IEC 60068-2-27 (non-operational shock, 65-80G, 9ms, trapezoidal) MIL-STD-810, Method 514.4 IEC 60068-2-6 (vibration-sinusiodal, 5Hz-150Hz)
|
Corrosion |
IEC 60068-2-52 (salt fog) IEC 60068-2-60 (flowing mixed gas) |