• +1866-852-5315
  • Login

Omababy V3 PRO Hands-free Hospital Grade Pump FAQ

                                        
Omababy V3 PRO HANDS FREE WEARABLE BREAST PUMP offers lightweight,quiet, portable, comfort and powerful suction. It is designed with a closed system pumping action, this ensures that the breast milk extracted is not exposed to any potential bacteria/germs. Omababy V3 PRO breast pumps are definitely your solution to enjoy an ultimate pumping experience. 
Our advanced suction technology ensuring maximum milk flow and comfort. The discreet wearable pump design makes it possible to pump ANYWHERE, ANYTIME weather it is pumping at work, in public, or on-the-go. 
                                  
V3 PRO Wearable Breast Pumps are easy to use and clean, making it the perfect choice for busy mums who want to provide their little ones with the best possible nutrition while keeping up with busy mum life.

Warranty

A 12-months warranty is provided on these Omababy’s electrical product: Omababy V3 PRO HANDSFREE WEARABLE BREAST PUMP motor unit from the date of purchase. 

The expression parts are not under warranty and should be replaced as needed.  The soft silicone shield and diaphragm should be replaced at the first signs of weakening (we recommend every 3 months depending on the amount of use and the condition after cleaning and sterilising).

For more information on Omababy V3 PRO Wearable Breast Pump Warranty, click here.  

Cleaning of Breast-pump parts

Sterilise all parts prior to first use and after each use,except  pump motor, bra adjustment strap and USB-C Charging cable. Rinse and wash by hand using warm soapy water (parts cannot be used in the dishwasher). It is important to be gentle when cleaning the valve and silicone diaphragm as these components are fragile and if damaged, it can cause suction levels to drop. Do not insert any object as it may cause damage to the components to tear. 

Rinse thoroughly, then sterilise and dry. The parts must be totally dry before assembling to pump.  

All of our accessories are suitable for use in UV & steam sterilisers (Maximum 5 mins, do not exceed 100 degrees celsius). However please note that it is not recommended to sterilise the accessories under high heat for long hours as it might cause the material to degenerate quicker, shortening the lifespan of the parts.

** All V3 PRO WEARABLE BREAST PUMP components (duckbill valve, flange inserts, milk collector cup and silicone breast shield are not suitable for high heat sterilization such as microwave sterilizer and dishwasher as this will damage the components/accessories. ** 

Do not use any implements or cloths when washing the breast pump parts, as they may tear the delicate silicone parts.

Any damage caused by improper cleaning and maintenance method will void the warranty.  

Please Note:

  • If you are using the boiling method, please only allow pump parts to sit in boiling water for 5 minutes as anytime longer than this can damage the accessories. Allow parts to cool before next use.
  • Please allow a maximum of 5-10 minutes drying time with UV sterilisers as over-sterilisation can damage the pump accessories.

N.B. The pump unit do not come in contact with the milk so they DO NOT need to be sterilised. 

Caring for the battery: 

The lithium battery should be kept at room temperature between 20-25 degrees and should never be subjected to elevated temperatures. Please do not leave the battery in or charged the breast pump in a hot car/ hot environment as heat reduces the lithium-ion battery life. 

Batteries deteriorate over time whether they are being used or not. It is best to charge the pump after every use to preserve the battery life and do not allow the battery to goes completely flat. 

Omababy V3 PRO Modes: 

The breast pump has 4 modes: Massage, Pumping, Lactation and Automatic.  It is recommended to run the breast pump in the automatic mode unless you wish to have more control over your pumping strength and speed.

The breast pump has 12 levels intensity: Up to 300mmHG, it offers more suction adjustment and precise suction force for each breast with less pain and more let-down. It is recommended to  always start with suction strength low then build up the strength slowly until you have reached a comfortable suction strength.  

Omababy's V3 PRO Wearable Breast Pump provides you the flexibility to pump anywhere, anytime whether you're at work, running errands, or out for a walk. Their lightweight and hands-free design means you can wear them comfortably for as long as you need without worrying about the hassle of cords or bulky equipment.

                          

When should I change the breast-pump parts?

It is recommended that all silicone parts including duck valve are replaced regularly. This is to ensure you can still have maximum milk extraction as this can affect the efficiency of milk extraction.  

Each V3 PRO Breast pump comes with a replacement duck valve, once you noticed that milk yield is less effective, please replace duck valve immediately.

The V3 PRO Hospital Grade Breast-pump is hospital-grade and this ensures you of its power, efficiency and durability. It is a smart little gadget that provides more advanced pumping features and more comfortable silicone on the breast, allowing powerful yet comfortable pumping. It has exceptional stimulation and expression levels to choose from, all safe with consideration for the mother's comfort.

To properly maintain your V3 PRO,  you’ll need to replace parts on a regular basis. Not replacing parts will make your pump work harder, leading to unnecessary wear and tear on the motor.

● Duck Valve: Replace every 4-5 weeks, or when you notice any damage or decrease in suction 

● Breastshield: Replace every 6 months, or when you notice any damage or decrease in suction 

● Diaphragm: Replace every 6-8 weeks, or when you notice any damage or decrease in suction

Flange: Replace every 3-5 months, or when you notice any damage or decrease in suction 

Why is my breast pump leaking from the flange when pumping? 

It is important to ensure that your flange is completely sealed all the way around before using. When parts are not completely dry before assembly it may cause the silicone edge to not snap in place, in turn, causing a leak. 

Heat sterilizing, or placing parts in dishwashers and microwaves are not recommended and may cause your silicone to warp out of shape, which may also cause leakage when pumping. 

To avoid leakage from the flange hole, avoid leaning back too much whilst pumping, to prevent the milk to fall back rather that into the collection cup. It may also be caused by damage to your valve. If there is a tear or the split has opened too much, this will allow for milk to travel back up rather than enter into the cup. 

Leaking when taking pump out of bra: 

To avoid the bottom of your collection cup getting caught on your bra it is recommended to tilt forward 45 degrees and slowly pull out the pump after your session. Try to give yourself as much space, by either unclipping an extender or clip to take out the pump.

Why do I feel pain when I use the breast pump?

Experiencing pain whilst breast-pumping is certainly not what we want, There are many reasons why you may experience pain while expressing, such as: 

Suction Level
The suction on the pump may be too high, please adjust the suction settings for a lower suction strength.

Cracked and sore Nipples
Your nipples may be cracked and is sore due to breastfeeding. If this is the case, stop using the breast pump for a while until your nipples have recovered. 

N.B. If there is any soreness when pumping, please reduce the settings. Please apply some breast milk or nipple cream on the nipple and areola if there is pinching so that the breast does not stick to the silicone and cause further pain and bleeding. 

Flange Sizes

Omababy V3 PRO comes with 24mm silicone shield and it comes with 2  complimentary flange inserts (19mm and 21mm) in order to provide maximum comfort during your pumping sessions.

The size of the shield's nipple area should be bigger than the nipple diameter.  Always centre the nipple shield with your nipple in the middle where it is able to move freely so your milk-ducts don't get blocked.

The areola should be mostly supported by the shield, but if is also fine if some are drawn into the nipple area.  If it is comfortable and the milk is expressing, this is a good sign.
Flange Sizing Guide 
The Omababy V3 PRO comes with complementary flange size 19mm and 21mm. This is the most commonly fitted sizes. 
A properly sized flange size is important to ensure the best performance of your pump. An improperly fitted flange size can cause discomfort, hinder milk output, and in severe cases cause injury.
To determine the flange size you need, pump for 5 minutes using the provided shields. Your nipples will expand while milk is being expressed so it’s important to measure after they have swollen to ensure the size you select will provide enough room. After you pump, measure the diameter of the nipples at the base as illustrated in the image to the right. Repeat the process a few times to make sure you have the right measurement. Select a flange size that is 2-3mm larger than this measurement.
Signs that your flange might be too small 
  • General discomfort while pumping
  • Painful rubbing of nipple in flange
  •  Nipple not moving freely inside of flange 
  • Redness of the nipple
  • Whiteness of the nipple and/or a white ring around the base of the nipple
  • Little milk is being expressed
Signs that your flange might be too big
  • General discomfort while pumping
  • Nipple is pulled to the end of the flange
  • Little milk is being expressed
  • Excess areola is drawn into the flange
  • Sensation of pulling and/or pulling pain

Can I pump and breastfeed at the same time?

Yes. With Omababy V3 PRO you can breastfeed and pump at the same time. No need to worry about the dangling bottle, tubes or cords.

For further information on our V3 PRO WEARABLE HANDSFREE Hospital Grade Breast-pump, please visit product page, click here

Newsletter

Subscribe to our newsletter and get 30% off your first purchase